Skip to content
24/7 emergency
778-938-5311
← All articles

No Hot Water From Your Gas Heater? Checks and Next Steps

No Hot Water From Your Gas Heater? Checks and Next Steps

Gas storage water heater in a home utility closet

When a gas water heater stops making hot water, the cause is often simple: a pilot that went out, a control knob sitting on the wrong setting, a closed gas valve, or a power-vent unit that lost power. Check those first, in the order below. If you smell gas, see scorching, or the pilot will not stay lit, stop and call a licensed gas fitter. Anything inside the burner area or the gas control is gas work, and it is not a job for a handyman. In Port Coquitlam, Coquitlam and Port Moody, we answer 24/7 at Paradigm Services. Jon, the owner, is the technician who shows up.

Paradigm Services and Installations
paradigmservices.ca
Get Help With Gas Heater Problems
If safe checks do not restore hot water, Paradigm provides gas fitting and emergency plumbing across the Tri-Cities, 24 hours a day.
Visit

TL;DR

  • Smell gas? Do not light anything or touch switches. Leave, then call your gas utility or 911 from outside.
  • Check the easy things first: gas supply on, gas control not on “vacation” or too low, pilot lit, power for power-vent and electronic-ignition units.
  • Relight a standing pilot only by following the label on the tank, and never when the tank is empty.
  • A pilot that keeps going out, a failed thermocouple, a bad gas control or any scorching means a licensed gas fitter.
  • Hot water that runs out fast on a tank that heats normally can be a broken dip tube, not a dead burner.

Table of Contents

Stop first: when this is not a troubleshooting job

Some signs end the checklist before it starts. Per a Canadian home-systems guide, stop and call if:

  • you smell gas (leave the house and call the gas utility or 911 from outside)
  • a carbon monoxide alarm sounds
  • there is soot, scorching or melted plastic at the top of the unit or around the burner
  • the heater has been under water, or water is reaching wiring or the electrical panel

If you smell gas, the manufacturer’s manual says not to light any appliance or touch switches, and to call the gas supplier from a neighbor’s phone. Use the fire department if you cannot reach the supplier. In the Tri-Cities, do not wait for morning. Our gas fitting service runs around the clock for exactly this.

Which type of heater do you have?

The checks depend on the heater, so find the label on the side of the unit.

  • Conventional tank with a standing pilot. A small flame burns all the time. It needs no electricity to run.
  • Tank with electronic ignition or power vent. There is no pilot flame. A fan or igniter needs power, so a tripped breaker or outage can mean no heat.
  • Tankless (on-demand). No stored water. It fires when you open a tap and often shows an error code or light.

This matters during a blackout. Natural Resources Canada says conventional gas-fired heaters do not require electricity and can provide hot water in an outage. A Saanich, BC study adds that this holds only for models with a continuous pilot. Units with electric ignition need power to start heating.

So can you have hot water with no gas? Only the water already stored in the tank. The Home Electrification Toolkit notes a conventional gas tank keeps supplying hot water without electricity until the stored water is used up. If the gas itself is cut off, the burner cannot reheat it.

The safe checks, in order

Four safe checks for a gas water heater

1. Confirm gas and power

Check that your other gas appliances work, such as the stove or furnace. If they are dead too, the problem is the supply and not the heater. Check that the manual gas shut-off valve on the heater’s gas line is open (handle in line with the pipe). Bosch Home Comfort Canada tells owners to verify the gas is on at the meter or propane tank and that all manual shut-off valves are open.

For power-vent or electronic-ignition units, check the breaker once. Reset it one time only. If it trips again, leave it.

If gas is out across your home, the utility’s guidance (from Alberta, but the principle is the same) is to call the emergency line and not relight appliances yourself until a technician gives instructions. In the Lower Mainland, call your gas utility.

2. Look at the temperature setting

Homeowner guidance from a Canadian builder says to confirm the setting is not on “vacation” or set too low. This happens more than people expect, especially after a house sitter or a tank that was shut off for a trip. Also make sure the water supply valve to the tank is open.

3. Check the pilot

On a standing-pilot tank, look through the small window or follow the label on the side of the tank. If the pilot is out, relight it as the label describes. A typical sequence:

  1. Turn the on-off-pilot knob to pilot.
  2. Hold the red button while you light the pilot with a match.
  3. Keep holding the button for 30 to 60 seconds after it lights.
  4. Turn the knob to on.

If you smell gas at any step, stop. Your tank’s label wins over any general guide.

Two rules matter here. Never light the pilot when the tank is empty, and fill the tank before lighting the burner. If you ever need to shut the water off, turn off the gas first, then close the cold supply.

4. Check vents and error lights

On power-vent and tankless units, a blocked vent or an error code can lock the unit out. Clearing snow or debris from an outside vent is a reasonable owner task, as is cleaning a filter. A code that returns after one reset points to a part that needs a technician.

What a repeat failure usually means

If you relight the pilot and it goes out again, relighting is not the fix. The usual causes are:

  • A failing thermocouple. This is the safety sensor that proves the pilot is lit. When it fails, the gas control shuts off.
  • A defective gas control valve.
  • Clogged pilot or burner lines, or dirt in the gas line. Giant’s troubleshooting guide lists these along with the thermocouple and gas control as causes of no heat.
  • A tripped high-limit or overheat sensor. On the Therm 330 PN tankless, Bosch says pilot outages during use typically come from the overheat sensors interrupting the pilot circuit.

These are the parts a licensed gas technician should replace, including gas controls, thermocouples in sealed combustion chambers and wiring. Gas work in BC is regulated, and gas fitting should be done by a licensed gas fitter. Our gas fitting page covers that work.

If gas lines were recently worked on, air in the line can keep a pilot from lighting. Bosch describes a bleeding procedure, but a repeated no-light after gas work is a call for the fitter who did the work, or for us.

Hot water, but it runs out fast

If the tank heats but you only get a short shower, the burner may be fine.

  • Broken dip tube. A cracked dip tube lets cold water mix near the top, so the tank seems to run out much too quickly. On older tanks, small plastic flecks in faucet aerators can be a clue.
  • Cold winter inlet water on a tankless unit. Natural Resources Canada gives an example: a unit that delivers 15 L/min with 18°C inlet water delivers only about 11 L/min when the inlet is 5°C. Winter flow is lower than summer flow.
  • Rusty or discolored water. That is a separate problem, covered in our rusty hot water guide.

If you want a broader checklist that includes electric tanks and fixtures, see what to check before you call a plumber.

Tankless units: error codes and shutdowns

Tankless heaters shut down to protect themselves, so a code or a flashing light is information worth writing down. Note the code, reset once if the manual allows, and check that gas is on and the vent is clear. For a unit that keeps cutting out, a sensor that alerts you to leaks around the heater can give early warning of water damage while you wait for service. Repeated lockouts need a technician to check gas pressure at the inlet, which Bosch says a licensed gas technician should confirm.

Owner-safe versus gas fitter

Task Owner Licensed gas fitter
Check gas valve is open, other gas appliances work Yes
Raise a setting that was left on vacation Yes
Reset a breaker once Yes
Clear snow from an outside vent, clean a filter Yes
Relight a standing pilot per the label Yes, if no gas smell
Pilot keeps going out Yes
Replace thermocouple, gas control, wiring Yes
Check inlet gas pressure Yes
Any scorching, soot, CO alarm, water on the burner Yes, after leaving the area if you smell gas

The same logic applies to a seasonal home check. For rental owners, an autumn maintenance checklist is a handy way to catch a tired water heater before the cold sets in.

Perspective

Most no-hot-water calls we get start with a homeowner who has already done the sensible things: checked the knob, relit the pilot, reset the breaker. That is exactly right, and it saves time. The line we draw is the moment the problem is inside the gas side of the heater.

A pilot that will not stay lit is telling you something is wrong with a safety part. Our approach is to show up, diagnose it, and tell you straight whether it is a repair or time to replace the tank. You get an on-site quote, and the $60 call-out fee is waived if the work goes ahead. If the tank needs replacing, we haul the old one away at no extra cost.

I have been in the trade for over 20 years, and I am the one on the job. When you call us at night, you reach the person whose name is on the business.

Jon

When you need us

If the checks above did not bring the heat back, or you hit one of the stop signs, Water Heater Service & Installation covers repair and replacement of tank and tankless units. We serve homeowners, strata properties and property managers across Port Coquitlam, Coquitlam, Port Moody and Metro Vancouver. If it is after hours or water is escaping, use our 24/7 emergency plumbing line.

Paradigm Services and Installations

Property managers handling tenant calls: a heater with no hot water in one unit can mean the same fault across a building, so tell us how many units are affected when you call.

FAQ

Why is my gas water heater not heating?

The most common causes are a pilot that has gone out, a control set to vacation or too low, a closed gas valve, or a power-vent unit without power. A failing thermocouple or gas control can also stop heating. Work through the checks above and call a licensed gas fitter if the pilot will not stay lit.

Can I relight the pilot myself?

On a standing-pilot tank, you can follow the lighting instructions printed on the tank, as long as you smell no gas and the tank is full of water. Hold the button for 30 to 60 seconds after the flame appears. If it goes out again, stop and call a gas fitter.

Will a gas water heater work in a power outage?

A conventional gas tank with a continuous pilot does not need electricity. Models with electronic ignition or a power vent do. Once the stored water is used up, a tank that cannot ignite will not reheat it until power returns.

Should I turn off a gas water heater if there is no water?

Yes. Never light the pilot when the tank is empty, and turn the gas off before you close the cold water supply to the tank.

Sources